Technical specifications
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Rated operation power at AC-23, 400 V
-kW
Interlockable
No
Switching power at 400 V
-kW
Number of switches
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Version as maintenance-/service switch
No
Version as emergency stop installation
No
Max. rated operation voltage Ue AC
690V
Rated operating voltage
690 - 690V
Version as reversing switch
No
Rated permanent current at AC-23, 400 V
1600A
Rated permanent current Iu
1600A
Version as main switch
Yes
Rated short-time withstand current lcw
50kA
Version as safety switch
No
Rated permanent current at AC-21, 400 V
1600A
Number of poles
3
Motor drive integrated
No
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
No
Voltage release optional
Yes
Suitable for front mounting 4-hole
No
Motor drive optional
Yes
Type of electrical connection of main circuit
Bolt connection
Type of control element
Push button
Suitable for front mounting centre
No
Degree of protection (NEMA)
Other
Suitable for distribution board installation
Yes
Degree of protection (IP), front side
IP30
Suitable for intermediate mounting
No
Colour control element
Other
From same serie
1SDA073401R1 | E1.2N/MS 1600 3P F F

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Rated operation power at AC-23, 400 V
-kW
Interlockable
Switching power at 400 V
-kW
Number of switches
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally open contact
0
Version as maintenance-/service switch
Version as emergency stop installation
Max. rated operation voltage Ue AC
690V
Rated operating voltage
690 .. 690V
Version as reversing switch
Rated permanent current at AC-23, 400 V
1600A
Rated permanent current Iu
1600A
Version as main switch
Rated short-time withstand current lcw
50kA
Version as safety switch
Rated permanent current at AC-21, 400 V
1600A
Number of poles
3
Motor drive integrated
Device construction
Built-in device fixed built-in technique
Suitable for floor mounting
Voltage release optional
Suitable for front mounting 4-hole
Motor drive optional
Type of electrical connection of main circuit
Bolt connection
Type of control element
Push button
Suitable for front mounting centre
Degree of protection (NEMA)
Other
Suitable for distribution board installation
Degree of protection (IP), front side
IP30
Suitable for intermediate mounting
Colour control element
Other