Technical specifications
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Interlockable
No
Rated operation power at AC-23, 400 V
-kW
Switching power at 400 V
-kW
Number of switches
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
Rated permanent current Iu
1250A
Version as main switch
Yes
Rated permanent current at AC-23, 400 V
1250A
Rated operating voltage
690 - 690V
Rated permanent current at AC-21, 400 V
1250A
Version as emergency stop installation
No
Suitable for floor mounting
No
Number of poles
4
Version as maintenance-/service switch
No
Rated short-time withstand current lcw
66kA
Motor drive integrated
No
Suitable for front mounting 4-hole
No
Max. rated operation voltage Ue AC
690V
Voltage release optional
Yes
Version as safety switch
No
Device construction
Built-in device fixed built-in technique
Version as reversing switch
No
Motor drive optional
Yes
Suitable for distribution board installation
Yes
Suitable for intermediate mounting
No
Colour control element
Other
Type of control element
Push button
Degree of protection (IP), front side
IP30
Type of electrical connection of main circuit
Bolt connection
Suitable for front mounting centre
No
Degree of protection (NEMA)
Other
From same serie
1SDA073445R1 | E2.2N/MS 1250 4P FHR

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Interlockable
Rated operation power at AC-23, 400 V
-kW
Switching power at 400 V
-kW
Number of switches
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
0
Rated permanent current Iu
1250A
Version as main switch
Rated permanent current at AC-23, 400 V
1250A
Rated operating voltage
690 .. 690V
Rated permanent current at AC-21, 400 V
1250A
Version as emergency stop installation
Suitable for floor mounting
Number of poles
4
Version as maintenance-/service switch
Rated short-time withstand current lcw
66kA
Motor drive integrated
Suitable for front mounting 4-hole
Max. rated operation voltage Ue AC
690V
Voltage release optional
Version as safety switch
Device construction
Built-in device fixed built-in technique
Version as reversing switch
Motor drive optional
Suitable for distribution board installation
Suitable for intermediate mounting
Colour control element
Other
Type of control element
Push button
Degree of protection (IP), front side
IP30
Type of electrical connection of main circuit
Bolt connection
Suitable for front mounting centre
Degree of protection (NEMA)
Other
From same serie