Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Number of poles3
Rated permanent current Iu250A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz85kA
Position of connection for main current circuitBack side
Number of auxiliary contacts as change-over contact4
Type of electrical connection of main circuitBolt connection
Suitable for DIN rail (top hat rail) mountingNo
With under voltage releaseNo
Adjustment range short-term delayed short-circuit release150.0 - 2500A
Overload release current setting100.0 - 250A
With switched-off indicatorYes
Motor drive optionalYes
Adjustment range undelayed short-circuit release375.0 - 3750A
Motor drive integratedNo
Type of control elementPush button
Integrated earth fault protectionYes
Degree of protection (IP)IP30
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA073630R1 | E2.2S 250 EKIP DIP LSIG 3P F HR

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Number of poles

3

Rated permanent current Iu

250A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

85kA

Position of connection for main current circuit

Back side

Number of auxiliary contacts as change-over contact

4

Type of electrical connection of main circuit

Bolt connection

Suitable for DIN rail (top hat rail) mounting

With under voltage release

Adjustment range short-term delayed short-circuit release

150.0 .. 2500A

Overload release current setting

100.0 .. 250A

With switched-off indicator

Motor drive optional

Adjustment range undelayed short-circuit release

375.0 .. 3750A

Motor drive integrated

Type of control element

Push button

Integrated earth fault protection

Degree of protection (IP)

IP30

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.