Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
250A
Device construction
Built-in device slide-in technique (withdrawable)
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
No
Motor drive optional
Yes
Adjustment range undelayed short-circuit release
375.0 - 3750A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Integrated earth fault protection
No
Number of poles
3
Overload release current setting
100.0 - 250A
Motor drive integrated
No
Position of connection for main current circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
Type of control element
Push button
Adjustment range short-term delayed short-circuit release
150.0 - 2500A
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
Rated voltage
690 - 690V
From same serie
1SDA073649R1 | E2.2S 250 EKIP DIP LSI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
250A
Device construction
Built-in device slide-in technique (withdrawable)
Complete device with protection unit
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
Motor drive optional
Adjustment range undelayed short-circuit release
375.0 .. 3750A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Integrated earth fault protection
Number of poles
3
Overload release current setting
100.0 .. 250A
Motor drive integrated
Position of connection for main current circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Type of control element
Push button
Adjustment range short-term delayed short-circuit release
150.0 .. 2500A
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
Rated voltage
690 .. 690V