Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Overload release current setting
100.0 - 250A
Rated permanent current Iu
250A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range short-term delayed short-circuit release
150.0 - 2500A
DIN rail (top hat rail) mounting optional
No
Integrated earth fault protection
Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Suitable for DIN rail (top hat rail) mounting
No
Rated voltage
690 - 690V
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
375.0 - 3750A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Yes
Motor drive optional
Yes
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Type of control element
Push button
Motor drive integrated
No
From same serie
1SDA073663R1 | E2.2S 250 EKIP TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Overload release current setting
100.0 .. 250A
Rated permanent current Iu
250A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range short-term delayed short-circuit release
150.0 .. 2500A
DIN rail (top hat rail) mounting optional
Integrated earth fault protection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Suitable for DIN rail (top hat rail) mounting
Rated voltage
690 .. 690V
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
375.0 .. 3750A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Motor drive optional
Degree of protection (IP)
IP30
Complete device with protection unit
Type of control element
Push button
Motor drive integrated
From same serie