  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Suitable for flush-mounted installationNo
Built-in depth82.5mm
Release characteristicK
Number of poles (total)1
Number of protected poles1
Rated current100A
Rated voltage230V
Rated insulation voltage Ui500V
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Voltage typeOther
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V16kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Frequency50 - 60Hz
Power loss8W
Flush-mounted installationNo
Current limiting class3
Concurrently switching neutral conductorNo
Over voltage category3
Pollution degree3
Additional equipment possibleYes
Width in number of modular spacings1.5
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section multi-wired0 - 50mm²
Connectable conductor cross section solid-core0 - 70mm²
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS811001R0637 | S801B-K100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Suitable for flush-mounted installation

Built-in depth

82.5mm

Release characteristic

K

Number of poles (total)

1

Number of protected poles

1

Rated current

100A

Rated voltage

230V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

Other

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

16kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Frequency

50 .. 60Hz

Power loss

8W

Flush-mounted installation

Current limiting class

3

Concurrently switching neutral conductor

Over voltage category

3

Pollution degree

3

Additional equipment possible

Width in number of modular spacings

1.5

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

0 .. 50mm²

Connectable conductor cross section solid-core

0 .. 70mm²

Explosion-proof

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.