Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Frequency50 - 60Hz
Built-in depth82.5mm
Pollution degree2
Rated insulation voltage Ui500V
Current limiting class3
Rated current80A
Release characteristicB
Rated voltage400V
Explosion-proofNo
Power loss12.8W
Width in number of modular spacings2
Degree of protection (IP)IP20
Over voltage category3
Ambient temperature during operating-25 - 60°C
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0 - 70mm²
Number of protected poles2
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Flush-mounted installationNo
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Number of poles (total)2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated impulse withstand voltage Uimp6kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS812001R0801 | S802B-D80

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Frequency

50 .. 60Hz

Built-in depth

82.5mm

Pollution degree

2

Rated insulation voltage Ui

500V

Current limiting class

3

Rated current

80A

Release characteristic

B

Rated voltage

400V

Explosion-proof

Power loss

12.8W

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Over voltage category

3

Ambient temperature during operating

-25 .. 60°C

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0 .. 70mm²

Number of protected poles

2

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Flush-mounted installation

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated impulse withstand voltage Uimp

6kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.