Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)IP20
Pollution degree3
Over voltage category3
Built-in depth82.5mm
Suitable for flush-mounted installationNo
Width in number of modular spacings4.5
Power loss24W
Number of protected poles3
Explosion-proofNo
Release characteristicC
Concurrently switching neutral conductorNo
Frequency50 - 60Hz
Rated insulation voltage Ui500V
Current limiting class3
Rated voltage400V
Voltage typeOther
Connectable conductor cross section solid-core0 - 70mm²
Rated current100A
Connectable conductor cross section multi-wired0 - 50mm²
Flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Number of poles (total)3
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V16kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
Rated impulse withstand voltage Uimp6kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS813001R0824 | S803B-C100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Pollution degree

3

Over voltage category

3

Built-in depth

82.5mm

Suitable for flush-mounted installation

Width in number of modular spacings

4.5

Power loss

24W

Number of protected poles

3

Explosion-proof

Release characteristic

C

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Rated insulation voltage Ui

500V

Current limiting class

3

Rated voltage

400V

Voltage type

Other

Connectable conductor cross section solid-core

0 .. 70mm²

Rated current

100A

Connectable conductor cross section multi-wired

0 .. 50mm²

Flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Number of poles (total)

3

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

16kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

Rated impulse withstand voltage Uimp

6kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.