Aleta.hr
Main Product Image

2CDS271061R0134 | S201M-C13UC

Code: 1617654

ManufacturerABB
Catalog number2CDS271061R0134
EAN code4013614430787

















Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)IP20
Voltage typeAC/DC
Suitable for flush-mounted installationNo
Width in number of modular spacings1
Rated voltage230V
Rated current13A
Built-in depth69mm
Release characteristicC
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of protected poles1
Connectable conductor cross section multi-wired0 - 25mm²
Connectable conductor cross section solid-core0 - 35mm²
Over voltage category3
Number of poles (total)1
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Additional equipment possibleYes
Pollution degree3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Power loss1.69W
Flush-mounted installationNo
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271061R0134 | S201M-C13UC

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC/DC

Suitable for flush-mounted installation

Width in number of modular spacings

1

Rated voltage

230V

Rated current

13A

Built-in depth

69mm

Release characteristic

C

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of protected poles

1

Connectable conductor cross section multi-wired

0 .. 25mm²

Connectable conductor cross section solid-core

0 .. 35mm²

Over voltage category

3

Number of poles (total)

1

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Additional equipment possible

Pollution degree

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Power loss

1.69W

Flush-mounted installation

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.