Technical specifications

Built-in depth69mm
Rated voltage230V
Voltage typeAC/DC
Rated current16A
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Connectable conductor cross section multi-wired0 - 25mm²
Pollution degree3
Current limiting class3
Over voltage category3
Connectable conductor cross section solid-core0 - 35mm²
Explosion-proofNo
Width in number of modular spacings1
Ambient temperature during operating-25 - 55°C
Flush-mounted installationNo
Number of protected poles1
Release characteristicB
Number of poles (total)1
Additional equipment possibleYes
Power loss2.47W
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271061R0165 | S201M-B16UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated voltage

230V

Voltage type

AC/DC

Rated current

16A

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Connectable conductor cross section multi-wired

0 .. 25mm²

Pollution degree

3

Current limiting class

3

Over voltage category

3

Connectable conductor cross section solid-core

0 .. 35mm²

Explosion-proof

Width in number of modular spacings

1

Ambient temperature during operating

-25 .. 55°C

Flush-mounted installation

Number of protected poles

1

Release characteristic

B

Number of poles (total)

1

Additional equipment possible

Power loss

2.47W

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Rated impulse withstand voltage Uimp