Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Rated current50A
Voltage typeAC/DC
Release characteristicC
Current limiting class3
Frequency50 - 60Hz
Over voltage category3
Rated insulation voltage Ui440V
Rated voltage230V
Degree of protection (IP)IP20
Number of protected poles1
Width in number of modular spacings1
Pollution degree3
Concurrently switching neutral conductorNo
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V-kA
Number of poles (total)1
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 25mm²
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS271061R0504 | S201M-C50UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated current

50A

Voltage type

AC/DC

Release characteristic

C

Current limiting class

3

Frequency

50 .. 60Hz

Over voltage category

3

Rated insulation voltage Ui

440V

Rated voltage

230V

Degree of protection (IP)

IP20

Number of protected poles

1

Width in number of modular spacings

1

Pollution degree

3

Concurrently switching neutral conductor

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

-kA

Number of poles (total)

1

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 25mm²

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

-kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.