Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Voltage typeAC/DC
Rated voltage400V
Frequency50 - 60Hz
Rated current13A
Connectable conductor cross section solid-core0 - 35mm²
Release characteristicB
Explosion-proofNo
Over voltage category3
Concurrently switching neutral conductorNo
Degree of protection (IP)IP20
Flush-mounted installationNo
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0 - 25mm²
Power loss4.72W
Pollution degree2
Rated insulation voltage Ui440V
Width in number of modular spacings2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Additional equipment possibleYes
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Number of protected poles2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272061R0135 | S202M-B13UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Voltage type

AC/DC

Rated voltage

400V

Frequency

50 .. 60Hz

Rated current

13A

Connectable conductor cross section solid-core

0 .. 35mm²

Release characteristic

B

Explosion-proof

Over voltage category

3

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Flush-mounted installation

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0 .. 25mm²

Power loss

4.72W

Pollution degree

2

Rated insulation voltage Ui

440V

Width in number of modular spacings

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Number of protected poles

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.