Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Concurrently switching neutral conductorNo
Over voltage category3
Rated current1.6A
Width in number of modular spacings2
Number of protected poles2
Current limiting class3
Rated insulation voltage Ui440V
Pollution degree2
Rated voltage400V
Degree of protection (IP)IP20
Built-in depth69mm
Frequency50 - 60Hz
Suitable for flush-mounted installationNo
Release characteristicK
Voltage typeAC/DC
Connectable conductor cross section solid-core0 - 35mm²
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0 - 25mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272061R0257 | S202M-K1,6UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Concurrently switching neutral conductor

Over voltage category

3

Rated current

1.6A

Width in number of modular spacings

2

Number of protected poles

2

Current limiting class

3

Rated insulation voltage Ui

440V

Pollution degree

2

Rated voltage

400V

Degree of protection (IP)

IP20

Built-in depth

69mm

Frequency

50 .. 60Hz

Suitable for flush-mounted installation

Release characteristic

K

Voltage type

AC/DC

Connectable conductor cross section solid-core

0 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0 .. 25mm²

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA