Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC/DC
Rated current3A
Rated voltage400V
Built-in depth69mm
Frequency50 - 60Hz
Width in number of modular spacings2
Number of protected poles2
Over voltage category3
Rated insulation voltage Ui440V
Release characteristicZ
Pollution degree2
Degree of protection (IP)IP20
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorNo
Number of poles (total)2
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 35mm²
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Ambient temperature during operating-25 - 55°C
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272061R0318 | S202M-Z3UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC/DC

Rated current

3A

Rated voltage

400V

Built-in depth

69mm

Frequency

50 .. 60Hz

Width in number of modular spacings

2

Number of protected poles

2

Over voltage category

3

Rated insulation voltage Ui

440V

Release characteristic

Z

Pollution degree

2

Degree of protection (IP)

IP20

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

Number of poles (total)

2

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 35mm²

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Ambient temperature during operating

-25 .. 55°C

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.