Technical specifications

Release characteristicC
Number of poles (total)2
Rated voltage400V
Rated insulation voltage Ui440V
Number of protected poles2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Rated current40A
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated impulse withstand voltage Uimp4kV
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Voltage typeAC/DC
Concurrently switching neutral conductorNo
Pollution degree2
Over voltage category3
Current limiting class3
Additional equipment possibleYes
Width in number of modular spacings2
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 55°C
Built-in depth69mm
Connectable conductor cross section multi-wired0 - 25mm²
Connectable conductor cross section solid-core0 - 35mm²
Suitable for flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS272061R0404 | S202M-C40UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

C

Number of poles (total)

2

Rated voltage

400V

Rated insulation voltage Ui

440V

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Rated current

40A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

4kV

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Voltage type

AC/DC

Concurrently switching neutral conductor

Pollution degree

2

Over voltage category

3

Current limiting class

3

Additional equipment possible

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

Built-in depth

69mm

Connectable conductor cross section multi-wired

0 .. 25mm²

Connectable conductor cross section solid-core

0 .. 35mm²

Suitable for flush-mounted installation

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.