Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)IP20
Voltage typeAC/DC
Suitable for flush-mounted installationNo
Width in number of modular spacings4
Rated current10A
Built-in depth69mm
Rated voltage400V
Release characteristicB
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0 - 25mm²
Number of protected poles4
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Number of poles (total)4
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Current limiting class3
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Pollution degree3
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Concurrently switching neutral conductorNo
Over voltage category3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Power loss8.12W
Flush-mounted installationNo
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274061R0105 | S204M-B10UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP20

Voltage type

AC/DC

Suitable for flush-mounted installation

Width in number of modular spacings

4

Rated current

10A

Built-in depth

69mm

Rated voltage

400V

Release characteristic

B

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0 .. 25mm²

Number of protected poles

4

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Current limiting class

3

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Pollution degree

3

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Concurrently switching neutral conductor

Over voltage category

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Power loss

8.12W

Flush-mounted installation

Explosion-proof

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.