Built-in depth69mm
Rated current0.5A
Voltage typeAC/DC
Over voltage category3
Frequency50 - 60Hz
Explosion-proofNo
Current limiting class3
Pollution degree3
Degree of protection (IP)IP20
Release characteristicK
Rated voltage400V
Rated insulation voltage Ui440V
Width in number of modular spacings4
Number of protected poles4
Power loss4.4W
Concurrently switching neutral conductorNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 25mm²
Ambient temperature during operating-25 - 55°C
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Number of poles (total)4
Connectable conductor cross section solid-core0 - 35mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274061R0157 | S204M-K0,5UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Rated current

0.5A

Voltage type

AC/DC

Over voltage category

3

Frequency

50 .. 60Hz

Explosion-proof

Current limiting class

3

Pollution degree

3

Degree of protection (IP)

IP20

Release characteristic

K

Rated voltage

400V

Rated insulation voltage Ui

440V

Width in number of modular spacings

4

Number of protected poles

4

Power loss

4.4W

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 25mm²

Ambient temperature during operating

-25 .. 55°C

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Number of poles (total)

4

Connectable conductor cross section solid-core

0 .. 35mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA