Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Release characteristicB
Rated current16A
Voltage typeAC/DC
Rated insulation voltage Ui440V
Frequency50 - 60Hz
Rated voltage400V
Over voltage category3
Pollution degree3
Current limiting class3
Power loss9.88W
Ambient temperature during operating-25 - 55°C
Flush-mounted installationNo
Explosion-proofNo
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Number of protected poles4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Width in number of modular spacings4
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Additional equipment possibleYes
Rated impulse withstand voltage Uimp4kV
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Number of poles (total)4
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-core0 - 35mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274061R0165 | S204M-B16UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Release characteristic

B

Rated current

16A

Voltage type

AC/DC

Rated insulation voltage Ui

440V

Frequency

50 .. 60Hz

Rated voltage

400V

Over voltage category

3

Pollution degree

3

Current limiting class

3

Power loss

9.88W

Ambient temperature during operating

-25 .. 55°C

Flush-mounted installation

Explosion-proof

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Number of protected poles

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Width in number of modular spacings

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Number of poles (total)

4

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

0 .. 35mm²

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.