Technical specifications

Built-in depth69mm
Power loss9.04W
Number of protected poles4
Degree of protection (IP)IP20
Current limiting class3
Over voltage category3
Voltage typeAC/DC
Rated insulation voltage Ui440V
Ambient temperature during operating-25 - 55°C
Frequency50 - 60Hz
Flush-mounted installationNo
Connectable conductor cross section solid-core0 - 35mm²
Width in number of modular spacings4
Concurrently switching neutral conductorNo
Release characteristicC
Pollution degree3
Connectable conductor cross section multi-wired0 - 25mm²
Explosion-proofNo
Suitable for flush-mounted installationNo
Rated current20A
Rated voltage400V
Additional equipment possibleYes
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274061R0204 | S204M-C20UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Power loss

9.04W

Number of protected poles

4

Degree of protection (IP)

IP20

Current limiting class

3

Over voltage category

3

Voltage type

AC/DC

Rated insulation voltage Ui

440V

Ambient temperature during operating

-25 .. 55°C

Frequency

50 .. 60Hz

Flush-mounted installation

Connectable conductor cross section solid-core

0 .. 35mm²

Width in number of modular spacings

4

Concurrently switching neutral conductor

Release characteristic

C

Pollution degree

3

Connectable conductor cross section multi-wired

0 .. 25mm²

Explosion-proof

Suitable for flush-mounted installation

Rated current

20A

Rated voltage

400V

Additional equipment possible

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA