Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree3
Rated insulation voltage Ui440V
Current limiting class3
Width in number of modular spacings4
Degree of protection (IP)IP20
Over voltage category3
Rated voltage400V
Release characteristicK
Rated current1.6A
Power loss6.48W
Frequency50 - 60Hz
Voltage typeAC/DC
Explosion-proofNo
Built-in depth69mm
Additional equipment possibleYes
Suitable for flush-mounted installationNo
Number of protected poles4
Connectable conductor cross section solid-core0 - 35mm²
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wired0 - 25mm²
Concurrently switching neutral conductorNo
Flush-mounted installationNo
Number of poles (total)4
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274061R0257 | S204M-K1,6UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Pollution degree

3

Rated insulation voltage Ui

440V

Current limiting class

3

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Over voltage category

3

Rated voltage

400V

Release characteristic

K

Rated current

1.6A

Power loss

6.48W

Frequency

50 .. 60Hz

Voltage type

AC/DC

Explosion-proof

Built-in depth

69mm

Additional equipment possible

Suitable for flush-mounted installation

Number of protected poles

4

Connectable conductor cross section solid-core

0 .. 35mm²

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

0 .. 25mm²

Concurrently switching neutral conductor

Flush-mounted installation

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.