Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristicZ
Number of poles (total)4
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Number of protected poles4
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorNo
Frequency50 - 60Hz
Rated current63A
Rated impulse withstand voltage Uimp4kV
Rated voltage400V
Width in number of modular spacings4
Voltage typeAC/DC
Connectable conductor cross section solid-core0 - 35mm²
Over voltage category3
Connectable conductor cross section multi-wired0 - 25mm²
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Current limiting class3
Pollution degree3
Additional equipment possibleYes
Degree of protection (IP)IP20
Built-in depth69mm
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274061R0608 | S204M-Z63UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Release characteristic

Z

Number of poles (total)

4

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of protected poles

4

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Frequency

50 .. 60Hz

Rated current

63A

Rated impulse withstand voltage Uimp

4kV

Rated voltage

400V

Width in number of modular spacings

4

Voltage type

AC/DC

Connectable conductor cross section solid-core

0 .. 35mm²

Over voltage category

3

Connectable conductor cross section multi-wired

0 .. 25mm²

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Current limiting class

3

Pollution degree

3

Additional equipment possible

Degree of protection (IP)

IP20

Built-in depth

69mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.