Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category3
Rated voltage400V
Current limiting class3
Rated insulation voltage Ui440V
Release characteristicC
Degree of protection (IP)IP20
Rated current63A
Concurrently switching neutral conductorNo
Number of protected poles4
Power loss22.36W
Explosion-proofNo
Voltage typeAC/DC
Width in number of modular spacings4
Built-in depth69mm
Pollution degree3
Frequency50 - 60Hz
Connectable conductor cross section solid-core0 - 35mm²
Additional equipment possibleYes
Connectable conductor cross section multi-wired0 - 25mm²
Flush-mounted installationNo
Number of poles (total)4
Ambient temperature during operating-25 - 55°C
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V10kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CDS274061R0634 | S204M-C63UC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Over voltage category

3

Rated voltage

400V

Current limiting class

3

Rated insulation voltage Ui

440V

Release characteristic

C

Degree of protection (IP)

IP20

Rated current

63A

Concurrently switching neutral conductor

Number of protected poles

4

Power loss

22.36W

Explosion-proof

Voltage type

AC/DC

Width in number of modular spacings

4

Built-in depth

69mm

Pollution degree

3

Frequency

50 .. 60Hz

Connectable conductor cross section solid-core

0 .. 35mm²

Additional equipment possible

Connectable conductor cross section multi-wired

0 .. 25mm²

Flush-mounted installation

Number of poles (total)

4

Ambient temperature during operating

-25 .. 55°C

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.