Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Rated permanent current Iu1600A
Integrated earth fault protectionNo
Overload release current setting640.0 - 1600A
Rated voltage1000 - 1000V
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release2400.0 - 24000A
With under voltage releaseNo
Type of electrical connection of main circuitBolt connection
Degree of protection (IP)IP30
Number of poles3
Complete device with protection unitYes
Motor drive integratedNo
Position of connection for main current circuitBack side
Number of auxiliary contacts as change-over contact4
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementPush button
With switched-off indicatorYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA069478R1 | E2N/VF 1600 PR122VF In1600A 3p FHR 1000V

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Rated permanent current Iu

1600A

Integrated earth fault protection

Overload release current setting

640.0 .. 1600A

Rated voltage

1000 .. 1000V

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

2400.0 .. 24000A

With under voltage release

Type of electrical connection of main circuit

Bolt connection

Degree of protection (IP)

IP30

Number of poles

3

Complete device with protection unit

Motor drive integrated

Position of connection for main current circuit

Back side

Number of auxiliary contacts as change-over contact

4

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

Type of control element

Push button

With switched-off indicator