Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage releaseNo
Rated permanent current Iu250A
Number of poles3
Rated voltage1000 - 1000V
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Overload release current setting100.0 - 250A
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
Type of control elementToggle
Motor drive integratedNo
With switched-off indicatorNo
Type of electrical connection of main circuitBolt connection
Position of connection for main current circuitFront side
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release250 - 3250A
Adjustment range short-term delayed short-circuit release- - -A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA063434R1 | T4L 250 PR222MP In=100 3p F FC 1000V AC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Rated permanent current Iu

250A

Number of poles

3

Rated voltage

1000 .. 1000V

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

100.0 .. 250A

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

Type of control element

Toggle

Motor drive integrated

With switched-off indicator

Type of electrical connection of main circuit

Bolt connection

Position of connection for main current circuit

Front side

Motor drive optional

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

250 .. 3250A

Adjustment range short-term delayed short-circuit release

- .. -A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA