Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Overload release current setting350.0 - 500A
Degree of protection (IP)IP20
Number of auxiliary contacts as normally closed contact0
Type of control elementToggle
Adjustment range short-term delayed short-circuit release- - -A
Motor drive optionalYes
With switched-off indicatorNo
Position of connection for main current circuitFront side
Integrated earth fault protectionNo
Type of electrical connection of main circuitBolt connection
With under voltage releaseNo
Motor drive integratedNo
Adjustment range undelayed short-circuit release2500 - 5000A
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
Device constructionBuilt-in device fixed built-in technique
Rated permanent current Iu630A
Number of poles3
Rated voltage1150 - 1150V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA063439R1 | T5V 630 TMA 500-5000 3p F FC 1150V AC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Overload release current setting

350.0 .. 500A

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally closed contact

0

Type of control element

Toggle

Adjustment range short-term delayed short-circuit release

- .. -A

Motor drive optional

With switched-off indicator

Position of connection for main current circuit

Front side

Integrated earth fault protection

Type of electrical connection of main circuit

Bolt connection

With under voltage release

Motor drive integrated

Adjustment range undelayed short-circuit release

2500 .. 5000A

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Rated permanent current Iu

630A

Number of poles

3

Rated voltage

1150 .. 1150V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA