  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting160.0 - 400A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Number of poles4
Rated permanent current Iu400A
Number of auxiliary contacts as normally closed contact0
Rated voltage1150 - 1150V
Motor drive integratedNo
Type of electrical connection of main circuitBolt connection
Degree of protection (IP)IP20
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Type of control elementToggle
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalNo
Adjustment range undelayed short-circuit release600.0 - 4800A
Adjustment range short-term delayed short-circuit release240.0 - 4000A
Integrated earth fault protectionYes
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
Complete device with protection unitYes
Position of connection for main current circuitFront side
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA063447R1 | T5V400 PR222DS/P-LSIG In400 4pFFC1150VAC

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting

160.0 .. 400A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Number of poles

4

Rated permanent current Iu

400A

Number of auxiliary contacts as normally closed contact

0

Rated voltage

1150 .. 1150V

Motor drive integrated

Type of electrical connection of main circuit

Bolt connection

Degree of protection (IP)

IP20

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Type of control element

Toggle

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

600.0 .. 4800A

Adjustment range short-term delayed short-circuit release

240.0 .. 4000A

Integrated earth fault protection

Motor drive optional

Device construction

Built-in device fixed built-in technique

With under voltage release

Complete device with protection unit

Position of connection for main current circuit

Front side