Aleta.hr
Main Product Image

1SDA063452R1 | T5V630 PR221DS-LS/I In630 4p FFC 1150VAC

Code: 1630133

ManufacturerABB
Catalog number1SDA063452R1
EAN code8015644660765

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
With integrated under voltage releaseNo
Rated permanent current Iu630A
Rated voltage1150 - 1150V
Overload release current setting252.0 - 630A
Adjustment range short-term delayed short-circuit release630 - 5985A
Adjustment range undelayed short-circuit release630 - 5985A
Integrated earth fault protectionNo
Type of electrical connection of main circuitBolt connection
With switched-off indicatorNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Type of control elementToggle
Position of connection for main current circuitFront side
Number of poles4
Complete device with protection unitYes
Degree of protection (IP)IP20
Motor drive integratedNo
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA063452R1 | T5V630 PR221DS-LS/I In630 4p FFC 1150VAC

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

With integrated under voltage release

Rated permanent current Iu

630A

Rated voltage

1150 .. 1150V

Overload release current setting

252.0 .. 630A

Adjustment range short-term delayed short-circuit release

630 .. 5985A

Adjustment range undelayed short-circuit release

630 .. 5985A

Integrated earth fault protection

Type of electrical connection of main circuit

Bolt connection

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Type of control element

Toggle

Position of connection for main current circuit

Front side

Number of poles

4

Complete device with protection unit

Degree of protection (IP)

IP20

Motor drive integrated

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.