ManufacturerABB
Catalog number1SDA067901R1
EAN code8015644017972

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting- - -A
Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu160A
Integrated earth fault protectionNo
With switched-off indicatorNo
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitBolt connection
Motor drive optionalYes
Complete device with protection unitYes
Type of control elementToggle
Adjustment range undelayed short-circuit release160 - 1600A
Motor drive integratedNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Suitable for DIN rail (top hat rail) mountingNo
Number of poles4
DIN rail (top hat rail) mounting optionalYes
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Rated voltage220 - 690V
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA067901R1 | XT2H 160 Ekip I In=160A 4p F F InN=100%

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting

- .. -A

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

160A

Integrated earth fault protection

With switched-off indicator

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Bolt connection

Motor drive optional

Complete device with protection unit

Type of control element

Toggle

Adjustment range undelayed short-circuit release

160 .. 1600A

Motor drive integrated

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Suitable for DIN rail (top hat rail) mounting

Number of poles

4

DIN rail (top hat rail) mounting optional

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Rated voltage

220 .. 690V

With under voltage release

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.