Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Frequency50 - 60Hz
Rated current50A
Rated voltage400V
Built-in depth82.5mm
Release characteristicK
Current limiting class3
Pollution degree3
Power loss17.2W
Rated insulation voltage Ui500V
Width in number of modular spacings4
Degree of protection (IP)IP20
Explosion-proofNo
Over voltage category3
Number of protected poles4
Concurrently switching neutral conductorNo
Connectable conductor cross section multi-wired0 - 70mm²
Suitable for flush-mounted installationNo
Ambient temperature during operating-25 - 60°C
Connectable conductor cross section solid-core0 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V10kA
Flush-mounted installationNo
Number of poles (total)4
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V10kA
Rated impulse withstand voltage Uimp6kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V16kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V16kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CCS814001R0577 | S804B-K50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Frequency

50 .. 60Hz

Rated current

50A

Rated voltage

400V

Built-in depth

82.5mm

Release characteristic

K

Current limiting class

3

Pollution degree

3

Power loss

17.2W

Rated insulation voltage Ui

500V

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Explosion-proof

Over voltage category

3

Number of protected poles

4

Concurrently switching neutral conductor

Connectable conductor cross section multi-wired

0 .. 70mm²

Suitable for flush-mounted installation

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

0 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Flush-mounted installation

Number of poles (total)

4

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

16kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

16kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.