Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current125A
Voltage typeAC
Rated voltage400V
Release characteristicB
Built-in depth75mm
Frequency50 - 60Hz
Number of protected poles2
Degree of protection (IP)IP20
Current limiting class3
Rated insulation voltage Ui440V
Width in number of modular spacings3
Pollution degree2
Explosion-proofNo
Over voltage category3
Connectable conductor cross section solid-core2.5 - 50mm²
Ambient temperature during operating-25 - 55°C
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Connectable conductor cross section multi-wired2.5 - 50mm²
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Additional equipment possibleYes
Flush-mounted installationNo
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

AZ-2-B125

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Rated current

125A

Voltage type

AC

Rated voltage

400V

Release characteristic

B

Built-in depth

75mm

Frequency

50 .. 60Hz

Number of protected poles

2

Degree of protection (IP)

IP20

Current limiting class

3

Rated insulation voltage Ui

440V

Width in number of modular spacings

3

Pollution degree

2

Explosion-proof

Over voltage category

3

Connectable conductor cross section solid-core

2.5 .. 50mm²

Ambient temperature during operating

-25 .. 55°C

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Additional equipment possible

Flush-mounted installation

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA