Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristicB
Built-in depth75mm
Rated impulse withstand voltage Uimp4kV
Rated insulation voltage Ui440V
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Rated voltage400V
Concurrently switching neutral conductorNo
Over voltage category3
Frequency50 - 60Hz
Number of poles (total)2
Number of protected poles1
Width in number of modular spacings2
Degree of protection (IP)IP20
Current limiting class3
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core2.5 - 50mm²
Pollution degree2
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Flush-mounted installationNo
Connectable conductor cross section multi-wired2.5 - 50mm²
Rated current16A
Additional equipment possibleYes
Voltage typeAC
Explosion-proofNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

AZ-2-B20

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

B

Built-in depth

75mm

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

440V

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated voltage

400V

Concurrently switching neutral conductor

Over voltage category

3

Frequency

50 .. 60Hz

Number of poles (total)

2

Number of protected poles

1

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Current limiting class

3

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

2.5 .. 50mm²

Pollution degree

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Flush-mounted installation

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Rated current

16A

Additional equipment possible

Voltage type

AC

Explosion-proof

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.