Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Frequency50 - 60Hz
Voltage typeAC
Rated voltage400V
Rated current63A
Built-in depth75mm
Rated insulation voltage Ui440V
Pollution degree2
Release characteristicB
Width in number of modular spacings3
Over voltage category3
Current limiting class3
Explosion-proofNo
Degree of protection (IP)IP20
Number of protected poles2
Connectable conductor cross section solid-core2.5 - 50mm²
Number of poles (total)2
Flush-mounted installationNo
Connectable conductor cross section multi-wired2.5 - 50mm²
Concurrently switching neutral conductorNo
Ambient temperature during operating-25 - 55°C
Additional equipment possibleYes
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

AZ-2-B63

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Frequency

50 .. 60Hz

Voltage type

AC

Rated voltage

400V

Rated current

63A

Built-in depth

75mm

Rated insulation voltage Ui

440V

Pollution degree

2

Release characteristic

B

Width in number of modular spacings

3

Over voltage category

3

Current limiting class

3

Explosion-proof

Degree of protection (IP)

IP20

Number of protected poles

2

Connectable conductor cross section solid-core

2.5 .. 50mm²

Number of poles (total)

2

Flush-mounted installation

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 55°C

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.