  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth75mm
Number of protected poles3
Voltage typeAC
Release characteristicB
Rated voltage400V
Number of poles (total)3
Rated current63A
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Frequency50 - 60Hz
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Concurrently switching neutral conductorNo
Current limiting class3
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Over voltage category3
Additional equipment possibleYes
Connectable conductor cross section multi-wired2.5 - 50mm²
Degree of protection (IP)IP20
Width in number of modular spacings4.5
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-core2.5 - 50mm²
Flush-mounted installationNo
Explosion-proofNo
Pollution degree2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

AZ-3-B63

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

75mm

Number of protected poles

3

Voltage type

AC

Release characteristic

B

Rated voltage

400V

Number of poles (total)

3

Rated current

63A

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Concurrently switching neutral conductor

Current limiting class

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Over voltage category

3

Additional equipment possible

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Degree of protection (IP)

IP20

Width in number of modular spacings

4.5

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

2.5 .. 50mm²

Flush-mounted installation

Explosion-proof

Pollution degree

2

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.