Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of protected poles3
Concurrently switching neutral conductorYes
Over voltage category3
Rated current100A
Connectable conductor cross section multi-wired2.5 - 50mm²
Pollution degree2
Built-in depth75mm
Width in number of modular spacings6
Frequency50 - 60Hz
Rated insulation voltage Ui440V
Explosion-proofNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Release characteristicB
Rated voltage400V
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V20kA
Flush-mounted installationNo
Additional equipment possibleYes
Degree of protection (IP)IP20
Ambient temperature during operating-25 - 55°C
Current limiting class3
Voltage typeAC
Connectable conductor cross section solid-core2.5 - 50mm²
Number of poles (total)4
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V20kA
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

AZ-3N-B100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Number of protected poles

3

Concurrently switching neutral conductor

Over voltage category

3

Rated current

100A

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Pollution degree

2

Built-in depth

75mm

Width in number of modular spacings

6

Frequency

50 .. 60Hz

Rated insulation voltage Ui

440V

Explosion-proof

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Release characteristic

B

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Flush-mounted installation

Additional equipment possible

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 55°C

Current limiting class

3

Voltage type

AC

Connectable conductor cross section solid-core

2.5 .. 50mm²

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

20kA

Rated impulse withstand voltage Uimp

4kV