Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage typeAC
Frequency50 - 60Hz
Built-in depth75mm
Explosion-proofNo
Release characteristicB
Current limiting class3
Rated current125A
Rated voltage400V
Over voltage category3
Pollution degree2
Rated insulation voltage Ui440V
Width in number of modular spacings6
Degree of protection (IP)IP20
Connectable conductor cross section solid-core2.5 - 50mm²
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V15kA
Concurrently switching neutral conductorNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V15kA
Ambient temperature during operating-25 - 55°C
Number of poles (total)4
Number of protected poles4
Additional equipment possibleYes
Flush-mounted installationNo
Connectable conductor cross section multi-wired2.5 - 50mm²
Rated impulse withstand voltage Uimp4kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

AZ-4-B125

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Voltage type

AC

Frequency

50 .. 60Hz

Built-in depth

75mm

Explosion-proof

Release characteristic

B

Current limiting class

3

Rated current

125A

Rated voltage

400V

Over voltage category

3

Pollution degree

2

Rated insulation voltage Ui

440V

Width in number of modular spacings

6

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

2.5 .. 50mm²

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

15kA

Ambient temperature during operating

-25 .. 55°C

Number of poles (total)

4

Number of protected poles

4

Additional equipment possible

Flush-mounted installation

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Rated impulse withstand voltage Uimp

4kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.