Built-in depth75mm
Frequency50 - 60Hz
Over voltage category3
Rated current50A
Voltage typeAC
Rated voltage400V
Release characteristicB
Pollution degree2
Rated insulation voltage Ui440V
Current limiting class3
Degree of protection (IP)IP20
Width in number of modular spacings6
Explosion-proofNo
Rated impulse withstand voltage Uimp4kV
Concurrently switching neutral conductorNo
Number of protected poles4
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Flush-mounted installationNo
Additional equipment possibleYes
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Connectable conductor cross section multi-wired2.5 - 50mm²
Number of poles (total)4
Connectable conductor cross section solid-core2.5 - 50mm²
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

AZ-4-B50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

75mm

Frequency

50 .. 60Hz

Over voltage category

3

Rated current

50A

Voltage type

AC

Rated voltage

400V

Release characteristic

B

Pollution degree

2

Rated insulation voltage Ui

440V

Current limiting class

3

Degree of protection (IP)

IP20

Width in number of modular spacings

6

Explosion-proof

Rated impulse withstand voltage Uimp

4kV

Concurrently switching neutral conductor

Number of protected poles

4

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Flush-mounted installation

Additional equipment possible

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Number of poles (total)

4

Connectable conductor cross section solid-core

2.5 .. 50mm²