  • EATON

Technical specifications

Release characteristicB
Frequency50 - 60Hz
Rated current10A
Built-in depth75mm
Number of protected poles1
Rated voltage400V
Voltage typeAC
Degree of protection (IP)IP20
Concurrently switching neutral conductorNo
Explosion-proofNo
Pollution degree2
Rated insulation voltage Ui440V
Over voltage category3
Width in number of modular spacings1
Number of poles (total)1
Connectable conductor cross section solid-core2.5 - 50mm²
Additional equipment possibleYes
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V6kA
Ambient temperature during operating-25 - 55°C
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V6kA
Connectable conductor cross section multi-wired2.5 - 50mm²
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V0kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

AZ-B100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Release characteristic

B

Frequency

50 .. 60Hz

Rated current

10A

Built-in depth

75mm

Number of protected poles

1

Rated voltage

400V

Voltage type

AC

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Explosion-proof

Pollution degree

2

Rated insulation voltage Ui

440V

Over voltage category

3

Width in number of modular spacings

1

Number of poles (total)

1

Connectable conductor cross section solid-core

2.5 .. 50mm²

Additional equipment possible

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Ambient temperature during operating

-25 .. 55°C

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

0kA