Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth75mm
Voltage typeAC
Rated insulation voltage Ui440V
Rated voltage230V
Explosion-proofNo
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Connectable conductor cross section solid-core2.5 - 50mm²
Number of protected poles1
Flush-mounted installationNo
Number of poles (total)1
Ambient temperature during operating-25 - 55°C
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Width in number of modular spacings1.5
Additional equipment possibleYes
Degree of protection (IP)IP20
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Current limiting class3
Pollution degree2
Rated current50A
Connectable conductor cross section multi-wired2.5 - 50mm²
Over voltage category3
Release characteristicB
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

AZ-B50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

75mm

Voltage type

AC

Rated insulation voltage Ui

440V

Rated voltage

230V

Explosion-proof

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

2.5 .. 50mm²

Number of protected poles

1

Flush-mounted installation

Number of poles (total)

1

Ambient temperature during operating

-25 .. 55°C

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Width in number of modular spacings

1.5

Additional equipment possible

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Current limiting class

3

Pollution degree

2

Rated current

50A

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Over voltage category

3

Release characteristic

B

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.