Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth75mm
Rated insulation voltage Ui440V
Rated impulse withstand voltage Uimp4kV
Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V0kA
Voltage typeAC
Rated voltage230V
Release characteristicD
Rated current20A
Number of poles (total)1
Number of protected poles1
Current limiting class3
Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V0kA
Flush-mounted installationNo
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V25kA
Frequency50 - 60Hz
Concurrently switching neutral conductorNo
Pollution degree2
Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V25kA
Over voltage category3
Width in number of modular spacings1.5
Connectable conductor cross section solid-core2.5 - 50mm²
Additional equipment possibleYes
Connectable conductor cross section multi-wired2.5 - 50mm²
Ambient temperature during operating-25 - 55°C
Explosion-proofNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

AZ-D20

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • EATON

Technical specifications

Built-in depth

75mm

Rated insulation voltage Ui

440V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

0kA

Voltage type

AC

Rated voltage

230V

Release characteristic

D

Rated current

20A

Number of poles (total)

1

Number of protected poles

1

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

0kA

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Frequency

50 .. 60Hz

Concurrently switching neutral conductor

Pollution degree

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Over voltage category

3

Width in number of modular spacings

1.5

Connectable conductor cross section solid-core

2.5 .. 50mm²

Additional equipment possible

Connectable conductor cross section multi-wired

2.5 .. 50mm²

Ambient temperature during operating

-25 .. 55°C

Explosion-proof

Degree of protection (IP)

IP20

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.