Degree of protection (IP)IP20
Number of poles2
Type of control elementRocker lever
Rated permanent current Iu100A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Overload release current setting0 - 0A
Rated voltage415 - 415V
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitScrew connection
Motor drive optionalNo
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release800 - 1200A
With under voltage releaseNo
With switched-off indicatorNo
Adjustment range short-term delayed short-circuit release0 - 0A
Position of connection for main current circuitFront side
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZMB1-2-A100

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP20

Number of poles

2

Type of control element

Rocker lever

Rated permanent current Iu

100A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

0 .. 0A

Rated voltage

415 .. 415V

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Screw connection

Motor drive optional

Motor drive integrated

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

800 .. 1200A

With under voltage release

With switched-off indicator

Adjustment range short-term delayed short-circuit release

0 .. 0A

Position of connection for main current circuit

Front side

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

DIN rail (top hat rail) mounting optional

Complete device with protection unit

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.