Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Type of electrical connection of main circuitScrew connection
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP20
Type of control elementRocker lever
Number of auxiliary contacts as change-over contact0
Rated voltage415 - 415V
Number of poles2
Rated permanent current Iu100A
Overload release current setting0 - 0A
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
Motor drive integratedNo
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release800 - 1200A
Adjustment range short-term delayed short-circuit release0 - 0A
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Motor drive optionalNo
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZMB1-2-A100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Type of electrical connection of main circuit

Screw connection

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP20

Type of control element

Rocker lever

Number of auxiliary contacts as change-over contact

0

Rated voltage

415 .. 415V

Number of poles

2

Rated permanent current Iu

100A

Overload release current setting

0 .. 0A

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Motor drive integrated

Integrated earth fault protection

Adjustment range undelayed short-circuit release

800 .. 1200A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Motor drive optional

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

With under voltage release

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.