Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Overload release current setting0 - 0A
Rated permanent current Iu20A
Motor drive integratedNo
Number of poles4
Degree of protection (IP)IP20
Rated voltage415 - 415V
Number of auxiliary contacts as normally closed contact0
Type of control elementRocker lever
Position of connection for main current circuitFront side
Type of electrical connection of main circuitScrew connection
With switched-off indicatorNo
With under voltage releaseNo
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Motor drive optionalNo
Adjustment range undelayed short-circuit release256 - 384A
Adjustment range short-term delayed short-circuit release0 - 0A
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZMB1-4-A20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Overload release current setting

0 .. 0A

Rated permanent current Iu

20A

Motor drive integrated

Number of poles

4

Degree of protection (IP)

IP20

Rated voltage

415 .. 415V

Number of auxiliary contacts as normally closed contact

0

Type of control element

Rocker lever

Position of connection for main current circuit

Front side

Type of electrical connection of main circuit

Screw connection

With switched-off indicator

With under voltage release

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Motor drive optional

Adjustment range undelayed short-circuit release

256 .. 384A

Adjustment range short-term delayed short-circuit release

0 .. 0A

Integrated earth fault protection

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.