Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP20
Number of poles4
Rated voltage415 - 415V
Rated permanent current Iu50A
Overload release current setting0 - 0A
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
With switched-off indicatorNo
Type of control elementRocker lever
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release0 - 0A
Motor drive integratedNo
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz25kA
Type of electrical connection of main circuitScrew connection
With under voltage releaseNo
Adjustment range undelayed short-circuit release480 - 720A
Motor drive optionalNo
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZMB1-4-A50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP20

Number of poles

4

Rated voltage

415 .. 415V

Rated permanent current Iu

50A

Overload release current setting

0 .. 0A

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

With switched-off indicator

Type of control element

Rocker lever

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

0 .. 0A

Motor drive integrated

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

25kA

Type of electrical connection of main circuit

Screw connection

With under voltage release

Adjustment range undelayed short-circuit release

480 .. 720A

Motor drive optional

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.