  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitFront side
Rated permanent current Iu160A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Number of poles3
Degree of protection (IP)IP20
Rated voltage415 - 415V
Overload release current setting0 - 0A
Type of control elementRocker lever
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Suitable for DIN rail (top hat rail) mountingNo
Motor drive integratedNo
With switched-off indicatorNo
Integrated earth fault protectionNo
Type of electrical connection of main circuitScrew connection
Adjustment range short-term delayed short-circuit release0 - 0A
Adjustment range undelayed short-circuit release1400 - 2100A
Motor drive optionalNo
With under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZMC2-A160

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Front side

Rated permanent current Iu

160A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Degree of protection (IP)

IP20

Rated voltage

415 .. 415V

Overload release current setting

0 .. 0A

Type of control element

Rocker lever

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Suitable for DIN rail (top hat rail) mounting

Motor drive integrated

With switched-off indicator

Integrated earth fault protection

Type of electrical connection of main circuit

Screw connection

Adjustment range short-term delayed short-circuit release

0 .. 0A

Adjustment range undelayed short-circuit release

1400 .. 2100A

Motor drive optional

With under voltage release

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Complete device with protection unit