Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Type of control elementRocker lever
With switched-off indicatorNo
Number of poles3
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz36kA
Number of auxiliary contacts as change-over contact0
Adjustment range short-term delayed short-circuit release0 - 0A
Rated voltage415 - 415V
Type of electrical connection of main circuitScrew connection
Adjustment range undelayed short-circuit release1400 - 2100A
Overload release current setting0 - 0A
Motor drive integratedNo
Rated permanent current Iu200A
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
Motor drive optionalNo
DIN rail (top hat rail) mounting optionalYes
With under voltage releaseNo
Complete device with protection unitYes
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZMC2-A200

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Type of control element

Rocker lever

With switched-off indicator

Number of poles

3

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA

Number of auxiliary contacts as change-over contact

0

Adjustment range short-term delayed short-circuit release

0 .. 0A

Rated voltage

415 .. 415V

Type of electrical connection of main circuit

Screw connection

Adjustment range undelayed short-circuit release

1400 .. 2100A

Overload release current setting

0 .. 0A

Motor drive integrated

Rated permanent current Iu

200A

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

Motor drive optional

DIN rail (top hat rail) mounting optional

With under voltage release

Complete device with protection unit

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.