Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu100A
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorNo
Number of poles2
Adjustment range short-term delayed short-circuit release0 - 0A
Type of control elementRocker lever
Adjustment range undelayed short-circuit release800 - 1200A
Overload release current setting0 - 0A
Number of auxiliary contacts as change-over contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz15kA
Suitable for DIN rail (top hat rail) mountingNo
Type of electrical connection of main circuitScrew connection
Number of auxiliary contacts as normally open contact0
Rated voltage415 - 415V
Motor drive optionalNo
Degree of protection (IP)IP20
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
With under voltage releaseNo
Motor drive integratedNo
Position of connection for main current circuitFront side
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZMD1-2-A100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

100A

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Number of poles

2

Adjustment range short-term delayed short-circuit release

0 .. 0A

Type of control element

Rocker lever

Adjustment range undelayed short-circuit release

800 .. 1200A

Overload release current setting

0 .. 0A

Number of auxiliary contacts as change-over contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

15kA

Suitable for DIN rail (top hat rail) mounting

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

0

Rated voltage

415 .. 415V

Motor drive optional

Degree of protection (IP)

IP20

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

With under voltage release

Motor drive integrated

Position of connection for main current circuit

Front side

Complete device with protection unit

DIN rail (top hat rail) mounting optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.