Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu25A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Overload release current setting0 - 0A
Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP20
Number of poles4
Rated voltage415 - 415V
Integrated earth fault protectionNo
Type of electrical connection of main circuitScrew connection
Adjustment range undelayed short-circuit release320 - 480A
Complete device with protection unitYes
Adjustment range short-term delayed short-circuit release0 - 0A
Position of connection for main current circuitFront side
With switched-off indicatorNo
Motor drive integratedNo
With under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz15kA
Motor drive optionalNo
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Type of control elementRocker lever
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZMD1-4-A25

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Rated permanent current Iu

25A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Overload release current setting

0 .. 0A

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP20

Number of poles

4

Rated voltage

415 .. 415V

Integrated earth fault protection

Type of electrical connection of main circuit

Screw connection

Adjustment range undelayed short-circuit release

320 .. 480A

Complete device with protection unit

Adjustment range short-term delayed short-circuit release

0 .. 0A

Position of connection for main current circuit

Front side

With switched-off indicator

Motor drive integrated

With under voltage release

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

15kA

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Type of control element

Rocker lever

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.