Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitFront side
Overload release current setting0 - 0A
Rated permanent current Iu25A
Number of poles1
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
Number of auxiliary contacts as normally closed contact0
Rated voltage240 - 240V
Type of control elementRocker lever
Type of electrical connection of main circuitScrew connection
Motor drive integratedNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz18kA
Adjustment range short-term delayed short-circuit release0 - 0A
Device constructionBuilt-in device fixed built-in technique
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalNo
With under voltage releaseNo
Motor drive optionalNo
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release320 - 480A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZME1-1-A25

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Front side

Overload release current setting

0 .. 0A

Rated permanent current Iu

25A

Number of poles

1

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally closed contact

0

Rated voltage

240 .. 240V

Type of control element

Rocker lever

Type of electrical connection of main circuit

Screw connection

Motor drive integrated

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

18kA

Adjustment range short-term delayed short-circuit release

0 .. 0A

Device construction

Built-in device fixed built-in technique

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

DIN rail (top hat rail) mounting optional

With under voltage release

Motor drive optional

Integrated earth fault protection

Adjustment range undelayed short-circuit release

320 .. 480A

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.