Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)IP20
Number of poles1
Type of control elementRocker lever
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu50A
Number of auxiliary contacts as normally open contact0
Motor drive optionalNo
Motor drive integratedNo
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitScrew connection
Overload release current setting0 - 0A
Device constructionBuilt-in device fixed built-in technique
Rated voltage240 - 240V
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release480 - 720A
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz18kA
Adjustment range short-term delayed short-circuit release0 - 0A
Position of connection for main current circuitFront side
With under voltage releaseNo
Complete device with protection unitYes
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZME1-1-A50

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Degree of protection (IP)

IP20

Number of poles

1

Type of control element

Rocker lever

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

50A

Number of auxiliary contacts as normally open contact

0

Motor drive optional

Motor drive integrated

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Screw connection

Overload release current setting

0 .. 0A

Device construction

Built-in device fixed built-in technique

Rated voltage

240 .. 240V

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

480 .. 720A

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

18kA

Adjustment range short-term delayed short-circuit release

0 .. 0A

Position of connection for main current circuit

Front side

With under voltage release

Complete device with protection unit

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.