Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of poles1
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu50A
Overload release current setting0 - 0A
Rated voltage240 - 240V
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
Motor drive integratedNo
Adjustment range undelayed short-circuit release480 - 720A
Position of connection for main current circuitFront side
Type of electrical connection of main circuitScrew connection
Adjustment range short-term delayed short-circuit release0 - 0A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz18kA
Type of control elementRocker lever
Degree of protection (IP)IP20
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalNo
Integrated earth fault protectionNo
With under voltage releaseNo
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZME1-1-A50

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of poles

1

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

50A

Overload release current setting

0 .. 0A

Rated voltage

240 .. 240V

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

Motor drive integrated

Adjustment range undelayed short-circuit release

480 .. 720A

Position of connection for main current circuit

Front side

Type of electrical connection of main circuit

Screw connection

Adjustment range short-term delayed short-circuit release

0 .. 0A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

18kA

Type of control element

Rocker lever

Degree of protection (IP)

IP20

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

Integrated earth fault protection

With under voltage release

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.