Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally closed contact0
Number of poles2
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
Overload release current setting0 - 0A
Rated permanent current Iu20A
Rated voltage415 - 415V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz18kA
Type of control elementRocker lever
Type of electrical connection of main circuitScrew connection
Motor drive integratedNo
With switched-off indicatorNo
Motor drive optionalNo
Adjustment range short-term delayed short-circuit release0 - 0A
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release256 - 384A
With under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZME1-2-A20

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally closed contact

0

Number of poles

2

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

Overload release current setting

0 .. 0A

Rated permanent current Iu

20A

Rated voltage

415 .. 415V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

18kA

Type of control element

Rocker lever

Type of electrical connection of main circuit

Screw connection

Motor drive integrated

With switched-off indicator

Motor drive optional

Adjustment range short-term delayed short-circuit release

0 .. 0A

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

256 .. 384A

With under voltage release

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.