Technical specifications

Number of auxiliary contacts as normally closed contact0
Rated permanent current Iu32A
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Overload release current setting0 - 0A
Number of poles2
Position of connection for main current circuitFront side
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz18kA
Motor drive integratedNo
Type of control elementRocker lever
Type of electrical connection of main circuitScrew connection
Device constructionBuilt-in device fixed built-in technique
With under voltage releaseNo
Complete device with protection unitYes
Adjustment range short-term delayed short-circuit release0 - 0A
Degree of protection (IP)IP20
Integrated earth fault protectionNo
Rated voltage415 - 415V
With switched-off indicatorNo
DIN rail (top hat rail) mounting optionalYes
Adjustment range undelayed short-circuit release320 - 480A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

BZME1-2-A32

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • EATON

Technical specifications

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

32A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Overload release current setting

0 .. 0A

Number of poles

2

Position of connection for main current circuit

Front side

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

18kA

Motor drive integrated

Type of control element

Rocker lever

Type of electrical connection of main circuit

Screw connection

Device construction

Built-in device fixed built-in technique

With under voltage release

Complete device with protection unit

Adjustment range short-term delayed short-circuit release

0 .. 0A

Degree of protection (IP)

IP20

Integrated earth fault protection

Rated voltage

415 .. 415V

With switched-off indicator

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

320 .. 480A